Skip Navigation
Skip to contents

JMD : Journal of Movement Disorders

OPEN ACCESS
SEARCH
Search

Articles

Page Path
HOME > J Mov Disord > Volume 10(3); 2017 > Article
Original Article
Quantitative Gait Analysis in Patients with Huntington’s Disease
Seon Jong Pyo1, Hanjun Kim1, Il Soo Kim1, Young-Min Park1, Mi-Jung Kim1, Hye Mi Lee2, Seong-Beom Koh1
Journal of Movement Disorders 2017;10(3):140-144.
DOI: https://doi.org/10.14802/jmd.17041
Published online: August 31, 2017

1Department of Neurology, Korea University Guro Hospital, Korea University College of Medicine, Seoul, Korea

2Department of Neurology, Korea SU Hospital, Seoul, Korea

Corresponding author: Seong-Beom Koh, MD, PhD, Department of Neurology and Parkinson’s Disease Center, Korea University Guro Hospital, Korea University College of Medicine, 148 Gurodong-ro, Guro-gu, Seoul 08308, Korea / Tel: +82-2-2626-1250 / Fax: +82-2-2626-1257 / E-mail: Parkinson@korea.ac.kr
• Received: June 23, 2017   • Revised: July 12, 2017   • Accepted: July 13, 2017

Copyright © 2017 The Korean Movement Disorder Society

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

prev next
  • 7,831 Views
  • 148 Download
  • 19 Web of Science
  • 20 Crossref
  • Objective
    Gait disturbance is the main factor contributing to a negative impact on quality of life in patients with Huntington’s disease (HD). Understanding gait features in patients with HD is essential for planning a successful gait strategy. The aim of this study was to investigate temporospatial gait parameters in patients with HD compared with healthy controls.
  • Methods
    We investigated 7 patients with HD. Diagnosis was confirmed by genetic analysis, and patients were evaluated with the Unified Huntington’s Disease Rating Scale (UHDRS). Gait features were assessed with a gait analyzer. We compared the results of patients with HD to those of 7 age- and sex-matched normal controls.
  • Results
    Step length and stride length were decreased and base of support was increased in the HD group compared to the control group. In addition, coefficients of variability for step and stride length were increased in the HD group. The HD group showed slower walking velocity, an increased stance/swing phase in the gait cycle and a decreased proportion of single support time compared to the control group. Cadence did not differ significantly between groups. Among the UHDRS subscores, total motor score and total behavior score were positively correlated with step length, and total behavior score was positively correlated with walking velocity in patients with HD.
  • Conclusion
    Increased variability in step and stride length, slower walking velocity, increased stance phase, and decreased swing phase and single support time with preserved cadence suggest that HD gait patterns are slow, ataxic and ineffective. This study suggests that quantitative gait analysis is needed to assess gait problems in HD.
Huntington’s disease (HD) is clinically characterized by involuntary movements such as chorea, psychiatric signs, and progressive dementia, with a prevalence of 0.38 per 100,000 people in Korea [1]. In addition, HD presents several changes in gait features, including decreased walking velocity, step initiation difficulties and variable stepping pattern [2-7]. As the disease progresses, mobility worsens not only through the development of hyperkinesia such as chorea but also through parkinsonian bradykinesia. Worsening of mobility due to gait problems is related to falls in patients with advanced HD, which further reduces functional capacity [8].
Understanding temporospatial parameters of gait in patients with HD is essential for planning a successful gait strategy, which consequently helps them avoid falls and improve their quality of daily living. Some studies have assessed gait patterns in patients with HD in North America and Europe [2,4,6,7,9,10]. The characteristic results include reduced walking speed, step length, and stride length, with increased stride time [2,6,10]. However, these studies have produced some contradictory results [2,4,6,9,10]. For example, Thaut et al. [4] did not find any evidence for a reduced cadence or stride length nor an increased stride time, and Hausdorff et al. [9] did not find any significant differences between patients with HD and controls except for a significant increase in stride-to-stride variability in gait cycle timing in patients with HD. Furthermore, there have been no studies that have assessed temporospatial gait parameters in Asian or Korean patients with HD. Previous research reported some differences between Asian HD patients and Caucasian HD patients, showing clinical differences such as a lower prevalence and higher proportion of patients without family history, and genetic differences included shorter CAG repeat length, different CAG distribution, HTT haplotype, and CCG polymorphism in Asian HD patients [1,11].
To understand gait changes in Korean patients with HD, we investigated temporospatial gait parameters using a gait analysis system and examined associations between gait parameters and clinical features using Unified Huntington’s Disease Rating Scale (UHDRS).
Subjects
We prospectively enrolled patients with HD according to the following inclusion criteria: 1) genetically confirmed HD patients (≥ 40 CAG repeat numbers in HTT gene), 2) patients were able to walk unassisted without falling during the gait study, and 3) patients were able to follow the investigator’s instructions, which meant that gait could not be influenced by cognitive or psychogenic problems. Seven patients (3 male and 4 female) with HD were re-cruited from May to December 2016 in the Korea University Guro Hospital. Control subjects were selected from our previously investigated dataset and were matched for age, sex and height with the patients with HD. Anyone exhibiting gait difficulty associated with musculoskeletal problems, previous stroke or head trauma, coexisting vestibulopathy, or significantly impaired cognition was excluded from the study. This study was approved by the Institutional Review Board of the Korea University Guro Hospital.
Assessment
Participants were characterized according to age, gender, height, weight, mini-mental status exam score, and disease duration and severity. Disease severity for the HD group was measured with the UHDRS for motor function, behavior and functional abilities: total motor score, total behavior score, functional checklist score, independence scale and total functional capacity score were measured [12]. Temporal and spatial gait characteristics of all subjects in both the HD group and the control group were measured using a gait analyzer (GaitRite. CIR system, Inc. - 12 fit AP1105; CIR systems, Franklin, NJ, USA). All participants walked at their usual speed and passed through the recording area of the gait analyzer. For each cycle, step length (cm), stride length (cm), and base of support were recorded as spatial gait parameters. Cadence (steps/min), walking velocity (cm/s), single and double support times (s), proportion in gait cycle (%GC) of single support and double support time, %GC of swing time and stance time were assessed as temporal gait parameters. Ten gait cycles were measured, and averages were calculated. For each parameter, intra-individual variability was assessed using the coefficient of variation (CoV).
Data analysis
Average values of bilateral sides were used for step length, stride length, base of support, CoV of step length, CoV of stride length, single and double support times, %GC of single and double support times, %GC of swing time and %GC of stance time. For comparisons of demographic, clinical and gait features between the HD group and the control group, Mann-Whitney U tests were used for continuous variables, and Fisher’s exact tests were used for categorical variables. For correlation analysis between UHDRS subscores and temporospatial gait parameters in the HD group, the correlation coefficients were determined using Spearman’s rank order correlation. A p-value < 0.05 was defined as statistically significant. All statistical analyses were performed with SPSS version 20.0 (IBM Corp., Armonk, NY, USA).
Demographic and clinical characteristics
Demographic features of all subjects in the HD group and the control group are presented in Table 1. Age, sex, height and weight did not differ significantly between groups. Clinical features of the HD group are also presented in Table 1. There was no significant correlation between age at onset and number of expanded CAG repeats in patients with HD. The number of expanded CAG repeats positively correlated with the UHDRS total motor score (Spearman’s rho coefficient = 0.861, p = 0.013) but did not correlate with the UHDRS total behavior score, functional checklist score, independence scale or total functional capacity.
Gait features
Most spatial and temporal parameters differed significantly between the HD and control groups (Table 2). Step and stride length were decreased and CoV of step and stride length were increased in the HD group compared to the control group. Base of support was wider in the HD group, but CoV of base of support was not significantly different between the HD group and the control group. Walking velocity was significantly decreased in HD patients. However, cadence did not differ significantly between the HD group and the control group. %GC of stance time was increased, and %GC of swing time was decreased in the HD group. Similarly, %GC of single support time was decreased in the HD group, but %GC of double support time was not significantly different between the HD group and the control group.
The relationship between gait parameters and clinical features
The UHDRS total motor score did not correlate with any gait parameters except step length. The UHDRS total motor score and step length showed a positive correlation (Spearman’s rho coefficient = 0.764, p = 0.046). The UHDRS total behavior score positively correlated with step length (Spearman’s rho coefficient = 0.800, p = 0.031) and with walking velocity (Spearman’s rho coefficient = 0.800, p = 0.031). The other UHDRS behavior scores did not show any significant correlation with any gait parameters. All of the functional assessment subscores (functional checklist score, independence scale and total functional capacity score) did not show any significant correlation with any gait parameters.
Gait disturbance is one of the most important and critical problems in patients with HD because gait disturbance, no less than motor dysfunction and psychiatric problems, is directly connected with quality of life and safety. Studies have assessed the gait patterns of patients with HD in Europe and North America. To our knowledge, this study is the first to analyze gait patterns in patients with HD in Korea. Like most analyses from other countries, the gait pattern of patients with HD in our study differed from that of normal controls. Until now, gait studies have produced somewhat contradictory results. The key findings were that HD patients show slow, ataxic, and irregular gait. Our investigation showed similar results (Table 3). Step and stride length were sh-orter, and walking velocity was slower in the HD group. These results were in accordance with previous gait studies in HD [2,6,10]. Variabilities in spatial gait parameters (for example, step length, stride length, and base of support) were significantly increased in the HD group compared to the control group, which suggests that patients with HD have large gait-to-gait variability. Irregular and non-patterned movement in patients with HD may influence this unexpected step and gait-to-gait variability. Furthermore, increased base of support and the changes in proportion of gait cycle (increased stance and swing phase, decreased proportion of single support time) showed that patients with HD had ataxic and somewhat cautious gait features. Despite the decreased gait velocity, the cadence in patients with HD did not change significantly. Compensation for slow walking velocity and short step length would increase the cadence. This type of compensation mechanism is observed in the early stage of Parkinson’s disease [13]. HD patients might lack the compensation for low velocity and short step lengths that appears in patients with Parkinson’s disease. On the other hand, despite their normal cadence, the low velocity suggests that even if patients with HD walk eagerly, it might not be efficient.
Motor dysfunction, such as chorea, dystonia, rigidity, and functional impairment, might be thought to influence gait disturbance in HD patients. In correlation analyses between the UHDRS subscores and gait parameters, the UHDRS total motor score and the behavior score both correlated with step length, which might suggest that patients with more severe motor or behavioral symptoms showed increased step length. Furthermore, the UHDRS total behavior score showed a positive correlation with walking velocity, which might mean that patients with more severe behavioral symptoms walk faster. Other gait parameters were not correlated with the UHDRS total behavior score or motor score. In addition, the functional component of the UHDRS sub-score did not correlate with any gait parameters. These results suggest that the UHDRS is insufficient to indicate the actual gait condition and strategy in HD patients. The sample size of this study was small, so interpretation of these correlation results is limited. Therefore, further studies with larger samples are needed to confirm the results of this study.
In conclusion, this study, patients with HD display some characteristic gait patterns, which were objectively assessed with a gait analyzer. Key findings from the analysis of temporospatial gait parameters show a slow, ataxic and inefficient gait without an increased cadence that would compensate for low velocity. In the future, a larger study is needed to replicate these findings.

Conflicts of Interest

The authors have no financial conflicts of interest.

We thank the patients with Huntington’s disease and the healthy volunteers for their willingness to participate in this study.
Table 1.
Demographic factors of HD patients and controls and clinical features of HD patients
Demographic and clinical features HD (n = 7) Control (n = 7) p-value*
Age (year) 59.14 ± 12.94 55.71 ± 14.58 0.481
Sex, male (%) 3 (42.9) 3 (42.9) > 0.999
Height (cm) 163.71 ± 6.13 162.71 ± 10.32 0.564
Weight (kg) 53.43 ± 9.34 54.14 ± 8.38 0.949
Age at onset (year) 52.29 ± 11.28
Disease duration (year) 6.86 ± 2.73
Number of expanded CAG repeats 43.14 ± 8.20
Number of normal CAG repeats 18.29 ± 12.42
UHDRS, total motor score 27.86 ± 8.44
UHDRS, total behavior score 9.57 ± 9.34
UHDRS, functional checklist score 19.57 ± 4.35
UHDRS, independence scale 80.00 ± 11.55
UHDRS, total functional capacity score 5.14 ± 1.68

Data are shown as the mean ± standard deviation for continuous variables and number (%) for categorical variables.

* statistical analyses were done with Mann-Whitney U tests for continuous variables and Fisher’s exact tests for categorical variables.

HD: Huntington’s disease, UHDRS: Unified Huntington’s Disease Rating Scale.

Table 2.
Comparison of gait parameters between the HD and control groups
HD (n = 7) Control (n = 7) p-value
Spatial parameters
 Step length (cm) 44.13 ± 9.06 60.14 ± 3.25 0.009
 CoV of step length (%) 19.54 ± 10.72 4.40 ± 1.62 0.002
 Stride length (cm) 89.06 ± 18.65 119.46 ± 5.88 0.009
 CoV of stride length (%) 12.97 ± 8.64 3.69 ± 1.59 0.003
 Base of support (cm) 12.83 ± 4.64 7.05 ± 3.05 0.025
 CoV of base of support (%) 34.80 ± 13.70 21.33 ± 7.44 0.064
Temporal parameters
 Walking velocity (cm/s) 72.53 ± 21.01 108.83 ± 15.36 0.009
 Cadence (steps/min) 97.49 ± 10.42 109.86 ± 18.53 0.085
 %GC of swing time 34.84 ± 2.59 38.37 ± 0.78 0.025
 %GC of stance time 65.16 ± 2.57 61.67 ± 0.64 0.025
 %GC of single support time 35.25 ± 2.38 38.45 ± 0.83 0.025
 %GC of double support time 29.95 ± 4.58 25.45 ± 6.02 0.142

All data are shown as the mean ± standard deviation. Statistical analysis was done with Mann-Whitney U tests. HD: Huntington’s disease, CoV: coefficient of variation, %GC: proportion in gait cycle.

Table 3.
Comparison of gait parameters between previous studies and present study
References WV (m/min) Cadence (steps/min) CoV of SL (%) SW (%GC) ST (%GC) SST (%GC) DST (%GC)
This study (n = 7) 72.53 ± 42.02 97.49 ± 20.84 12.97 ± 17.34 34.84 ± 7.68 65.16 ± 7.68 35.25 ± 8.36 29.95 ± 8.82
(Decreased) (No difference) (Increased) (Decreased) (Increased) (Decreased) (No difference)
Reynolds et al., 1999 (n = 6) 82.37 ± 52.60 93.83 ± 37.41 NA NA 65.43 ± 9.94 NA NA
(Decreased) (Decreased) (Increased)
Churchyard et al., 2001 (n = 20) 59.70 ± 42.60 100.60 ± 27.20 NA NA NA NA 34.80 ± 16.20
(Decreased) (Decreased) (No difference)
Koller et al., 1985 (n = 13) 76.00 ± 28.00 73.10 ± 0.19 NA NA NA NA NA
(Decreased) (Decreased)
Delval et al., 2006 (n = 15) 100.00 ± 74.00 101.85 ± 25.02 8.71 ± 17.36 NA NA 39.33 ± 10.78 22.13 ± 22.24
(Decreased) (Decreased) (Increased) (No difference) (No difference)
Hausdorff et al., 1998 (n = 20) 115.00 ± 70.00 NA NA 35.00 ± 7.20 NA NA 36.20 ± 18.00
(No difference) (No difference) (No difference)

All data are shown as the mean ± standard deviation. WV: walking velocity, CoV: coefficient of variation, SL: stride length, SW: swing time, %GC: proportion in gait cycle, ST: stance time, SST: single support time, DST: double support time, NA: not available.

  • 1. Kim HS, Lyoo CH, Lee PH, Kim SJ, Park MY, Ma HI, et al. Current status of Huntington’s disease in Korea: a nationwide survey and national registry analysis. J Mov Disord 2015;8:14–20.ArticlePubMedPMC
  • 2. Koller WC, Trimble J. The gait abnormality of Huntington’s disease. Neurology 1985;35:1450–1454.ArticlePubMed
  • 3. Rao AK, Muratori L, Louis ED, Moskowitz CB, Marder KS. Spectrum of gait impairments in presymptomatic and symptomatic Huntington’s disease. Mov Disord 2008;23:1100–1107.ArticlePubMed
  • 4. Thaut MH, Miltner R, Lange HW, Hurt CP, Hoemberg V. Velocity modulation and rhythmic synchronization of gait in Huntington’s disease. Mov Disord 1999;14:808–819.ArticlePubMed
  • 5. Bilney B, Morris ME, Churchyard A, Chiu E, Georgiou-Karistianis N. Evidence for a disorder of locomotor timing in Huntington’s disease. Mov Disord 2005;20:51–57.ArticlePubMed
  • 6. Churchyard AJ, Morris ME, Georgiou N, Chiu E, Cooper R, Iansek R. Gait dysfunction in Huntington’s disease: parkinsonism and a disorder of timing. Implications for movement rehabilitation. Adv Neurol 2001;87:375–385.PubMed
  • 7. Delval A, Krystkowiak P, Blatt JL, Labyt E, Dujardin K, Destée A, et al. Role of hypokinesia and bradykinesia in gait disturbances in Huntington’s disease: a biomechanical study. J Neurol 2006;253:73–80.ArticlePubMed
  • 8. Georgiou N, Bradshaw JL, Phillips JG, Chiu E, Bradshaw JA. Reliance on advance information and movement sequencing in Huntington’s disease. Mov Disord 1995;10:472–481.ArticlePubMed
  • 9. Hausdorff JM, Cudkowicz ME, Firtion R, Wei JY, Goldberger AL. Gait variability and basal ganglia disorders: stride-to-stride variations of gait cycle timing in Parkinson’s disease and Huntington’s disease. Mov Disord 1998;13:428–437.ArticlePubMed
  • 10. Reynolds NC Jr, Myklebust JB, Prieto TE, Myklebust BM. Analysis of gait abnormalities in Huntington disease. Arch Phys Med Rehabil 1999;80:59–65.ArticlePubMed
  • 11. Xu M, Wu ZY. Huntington disease in Asia. Chin Med J (Engl) 2015;128:1815–1819.ArticlePubMedPMC
  • 12. Unified Huntington’s Disease Rating Scale: reliability and consistency. Huntington Study Group. Mov Disord 1996;11:136–142.ArticlePubMed
  • 13. Nieuwboer A, Dom R, De Weerdt W, Desloovere K, Fieuws S, Broens-Kaucsik E. Abnormalities of the spatiotemporal characteristics of gait at the onset of freezing in Parkinson’s disease. Mov Disord 2001;16:1066–1075.ArticlePubMed

Figure & Data

References

    Citations

    Citations to this article as recorded by  
    • Sensor-Based Locomotion Data Mining for Supporting the Diagnosis of Neurodegenerative Disorders: A Survey
      Samaneh Zolfaghari, Sumaiya Suravee, Daniele Riboni, Kristina Yordanova
      ACM Computing Surveys.2024; 56(1): 1.     CrossRef
    • The semicircular canal function is preserved with little impact on falls in patients with mild Parkinson's disease
      Jun-Pyo Hong, Hanim Kwon, Euyhyun Park, Sun-Uk Lee, Chan-Nyoung Lee, Byung-Jo Kim, Ji-Soo Kim, Kun-Woo Park
      Parkinsonism & Related Disorders.2024; 118: 105933.     CrossRef
    • Gene-dosage- and sex-dependent differences in the prodromal-Like phase of the F344tgHD rat model for Huntington disease
      Veronika Ratz-Wirsching, Johanna Habermeyer, Sandra Moceri, Julia Harrer, Christoph Schmitz, Stephan von Hörsten
      Frontiers in Neuroscience.2024;[Epub]     CrossRef
    • Vision-based motion capture for the gait analysis of neurodegenerative diseases: A review
      David Sing Yee Vun, Robert Bowers, Anthony McGarry
      Gait & Posture.2024; 112: 95.     CrossRef
    • Estimation of Gait Parameters in Huntington’s Disease Using Wearable Sensors in the Clinic and Free-living Conditions
      Manuel Lozano-García, Emer P. Doheny, Elliot Mann, Philippa Morgan-Jones, Cheney Drew, Monica Busse-Morris, Madeleine M. Lowery
      IEEE Transactions on Neural Systems and Rehabilitation Engineering.2024; 32: 2239.     CrossRef
    • Wearable sensors and features for diagnosis of neurodegenerative diseases: A systematic review
      Huan Zhao, Junyi Cao, Junxiao Xie, Wei-Hsin Liao, Yaguo Lei, Hongmei Cao, Qiumin Qu, Chris Bowen
      DIGITAL HEALTH.2023;[Epub]     CrossRef
    • Spatiotemporal Gait Parameters in Adults With Premanifest and Manifest Huntington’s Disease: A Systematic Review
      Sasha Browning, Stephanie Holland, Ian Wellwood, Belinda Bilney
      Journal of Movement Disorders.2023; 16(3): 307.     CrossRef
    • Walking pattern analysis using GAIT cycles and silhouettes for clinical applications
      S.M.H. Sithi Shameem Fathima, K.A. Jyotsna, Thiruveedula Srinivasulu, Kande Archana, M. Tulasi rama, S. Ravichand
      Measurement: Sensors.2023; 30: 100893.     CrossRef
    • Human Gait Analysis in Neurodegenerative Diseases: A Review
      Grazia Cicirelli, Donato Impedovo, Vincenzo Dentamaro, Roberto Marani, Giuseppe Pirlo, Tiziana R. D'Orazio
      IEEE Journal of Biomedical and Health Informatics.2022; 26(1): 229.     CrossRef
    • Development of Neuro-Degenerative Diseases’ Gait Classification Algorithm Using Convolutional Neural Network and Wavelet Coherence Spectrogram of Gait Synchronization
      Febryan Setiawan, An-Bang Liu, Che-Wei Lin
      IEEE Access.2022; 10: 38137.     CrossRef
    • Artificial intelligence in neurodegenerative diseases: A review of available tools with a focus on machine learning techniques
      Alexandra-Maria Tăuţan, Bogdan Ionescu, Emiliano Santarnecchi
      Artificial Intelligence in Medicine.2021; 117: 102081.     CrossRef
    • Identification of Neurodegenerative Diseases Based on Vertical Ground Reaction Force Classification Using Time–Frequency Spectrogram and Deep Learning Neural Network Features
      Febryan Setiawan, Che-Wei Lin
      Brain Sciences.2021; 11(7): 902.     CrossRef
    • The effects of dual-task cognitive interference on gait and turning in Huntington’s disease
      Nicollette L. Purcell, Jennifer G. Goldman, Bichun Ouyang, Yuanqing Liu, Bryan Bernard, Joan A. O’Keefe, Pedro Gonzalez-Alegre
      PLOS ONE.2020; 15(1): e0226827.     CrossRef
    • Gait variability as digital biomarker of disease severity in Huntington’s disease
      Heiko Gaßner, Dennis Jensen, F. Marxreiter, Anja Kletsch, Stefan Bohlen, Robin Schubert, Lisa M. Muratori, Bjoern Eskofier, Jochen Klucken, Jürgen Winkler, Ralf Reilmann, Zacharias Kohl
      Journal of Neurology.2020; 267(6): 1594.     CrossRef
    • Evaluation of Vertical Ground Reaction Forces Pattern Visualization in Neurodegenerative Diseases Identification Using Deep Learning and Recurrence Plot Image Feature Extraction
      Che-Wei Lin, Tzu-Chien Wen, Febryan Setiawan
      Sensors.2020; 20(14): 3857.     CrossRef
    • Cerebral dopamine neurotrophic factor (CDNF) protects against quinolinic acid-induced toxicity in in vitro and in vivo models of Huntington’s disease
      P. Stepanova, V. Srinivasan, D. Lindholm, M. H. Voutilainen
      Scientific Reports.2020;[Epub]     CrossRef
    • Rapid and robust patterns of spontaneous locomotor deficits in mouse models of Huntington’s disease
      Taneli Heikkinen, Timo Bragge, Niina Bhattarai, Teija Parkkari, Jukka Puoliväli, Outi Kontkanen, Patrick Sweeney, Larry C. Park, Ignacio Munoz-Sanjuan, Yuqing Li
      PLOS ONE.2020; 15(12): e0243052.     CrossRef
    • Rule based classification of neurodegenerative diseases using data driven gait features
      Kartikay Gupta, Aayushi Khajuria, Niladri Chatterjee, Pradeep Joshi, Deepak Joshi
      Health and Technology.2019; 9(4): 547.     CrossRef
    • Discovery of Arginine Ethyl Ester as Polyglutamine Aggregation Inhibitor: Conformational Transitioning of Huntingtin N-Terminus Augments Aggregation Suppression
      Virender Singh, Kinjal A. Patel, Raj Kumar Sharma, Pratik R. Patil, Abhayraj S. Joshi, Rashmi Parihar, Thamarailingam Athilingam, Neeraj Sinha, Subramaniam Ganesh, Pradip Sinha, Ipsita Roy, Ashwani Kumar Thakur
      ACS Chemical Neuroscience.2019; 10(9): 3969.     CrossRef
    • Gait Biomarkers Classification by Combining Assembled Algorithms and Deep Learning: Results of a Local Study
      Eddy Sánchez-DelaCruz, Roberto Weber, R. R. Biswal, Jose Mejía, Gandhi Hernández-Chan, Heberto Gómez-Pozos
      Computational and Mathematical Methods in Medicine.2019; 2019: 1.     CrossRef

    Comments on this article

    Add a comment
    Quantitative Gait Analysis in Patients with Huntington’s Disease
    Quantitative Gait Analysis in Patients with Huntington’s Disease
    Demographic and clinical features HD (n = 7) Control (n = 7) p-value*
    Age (year) 59.14 ± 12.94 55.71 ± 14.58 0.481
    Sex, male (%) 3 (42.9) 3 (42.9) > 0.999
    Height (cm) 163.71 ± 6.13 162.71 ± 10.32 0.564
    Weight (kg) 53.43 ± 9.34 54.14 ± 8.38 0.949
    Age at onset (year) 52.29 ± 11.28
    Disease duration (year) 6.86 ± 2.73
    Number of expanded CAG repeats 43.14 ± 8.20
    Number of normal CAG repeats 18.29 ± 12.42
    UHDRS, total motor score 27.86 ± 8.44
    UHDRS, total behavior score 9.57 ± 9.34
    UHDRS, functional checklist score 19.57 ± 4.35
    UHDRS, independence scale 80.00 ± 11.55
    UHDRS, total functional capacity score 5.14 ± 1.68
    HD (n = 7) Control (n = 7) p-value
    Spatial parameters
     Step length (cm) 44.13 ± 9.06 60.14 ± 3.25 0.009
     CoV of step length (%) 19.54 ± 10.72 4.40 ± 1.62 0.002
     Stride length (cm) 89.06 ± 18.65 119.46 ± 5.88 0.009
     CoV of stride length (%) 12.97 ± 8.64 3.69 ± 1.59 0.003
     Base of support (cm) 12.83 ± 4.64 7.05 ± 3.05 0.025
     CoV of base of support (%) 34.80 ± 13.70 21.33 ± 7.44 0.064
    Temporal parameters
     Walking velocity (cm/s) 72.53 ± 21.01 108.83 ± 15.36 0.009
     Cadence (steps/min) 97.49 ± 10.42 109.86 ± 18.53 0.085
     %GC of swing time 34.84 ± 2.59 38.37 ± 0.78 0.025
     %GC of stance time 65.16 ± 2.57 61.67 ± 0.64 0.025
     %GC of single support time 35.25 ± 2.38 38.45 ± 0.83 0.025
     %GC of double support time 29.95 ± 4.58 25.45 ± 6.02 0.142
    References WV (m/min) Cadence (steps/min) CoV of SL (%) SW (%GC) ST (%GC) SST (%GC) DST (%GC)
    This study (n = 7) 72.53 ± 42.02 97.49 ± 20.84 12.97 ± 17.34 34.84 ± 7.68 65.16 ± 7.68 35.25 ± 8.36 29.95 ± 8.82
    (Decreased) (No difference) (Increased) (Decreased) (Increased) (Decreased) (No difference)
    Reynolds et al., 1999 (n = 6) 82.37 ± 52.60 93.83 ± 37.41 NA NA 65.43 ± 9.94 NA NA
    (Decreased) (Decreased) (Increased)
    Churchyard et al., 2001 (n = 20) 59.70 ± 42.60 100.60 ± 27.20 NA NA NA NA 34.80 ± 16.20
    (Decreased) (Decreased) (No difference)
    Koller et al., 1985 (n = 13) 76.00 ± 28.00 73.10 ± 0.19 NA NA NA NA NA
    (Decreased) (Decreased)
    Delval et al., 2006 (n = 15) 100.00 ± 74.00 101.85 ± 25.02 8.71 ± 17.36 NA NA 39.33 ± 10.78 22.13 ± 22.24
    (Decreased) (Decreased) (Increased) (No difference) (No difference)
    Hausdorff et al., 1998 (n = 20) 115.00 ± 70.00 NA NA 35.00 ± 7.20 NA NA 36.20 ± 18.00
    (No difference) (No difference) (No difference)
    Table 1. Demographic factors of HD patients and controls and clinical features of HD patients

    Data are shown as the mean ± standard deviation for continuous variables and number (%) for categorical variables.

    statistical analyses were done with Mann-Whitney U tests for continuous variables and Fisher’s exact tests for categorical variables.

    HD: Huntington’s disease, UHDRS: Unified Huntington’s Disease Rating Scale.

    Table 2. Comparison of gait parameters between the HD and control groups

    All data are shown as the mean ± standard deviation. Statistical analysis was done with Mann-Whitney U tests. HD: Huntington’s disease, CoV: coefficient of variation, %GC: proportion in gait cycle.

    Table 3. Comparison of gait parameters between previous studies and present study

    All data are shown as the mean ± standard deviation. WV: walking velocity, CoV: coefficient of variation, SL: stride length, SW: swing time, %GC: proportion in gait cycle, ST: stance time, SST: single support time, DST: double support time, NA: not available.


    JMD : Journal of Movement Disorders Twitter
    Close layer
    TOP